Replacement Fan Motor for Precision Water Distiller, Models 8-M, 5-3, 8-5, 8-8, 12-12, 12-20. Dual voltage 120/240. Item #060049.

Fan Motor – for Precision Water Distillers – Dual Voltage

This is a universal motor replacement for all Precision residential  model distillers. (Precision 8-M/8-8/12-12 )

Part # 060049 – MOTOR, 1/50HP, DUAL Voltage, 120/240V

** Notice !!  This item will be discontinued  – Order Motor #400184 – But know that it is 120V only! and 2 wire not 4.  Refer to Motor#400184 there are installation instructions to help with replacement.

Tools Required

11/32” Nut Driver or small Adjustable Wrench (Crescent Wrench)

Electrical Terminal Crimping Pliers

Wire Cutters

#2 Phillips Screwdriver

Red Robertson Screwdriver

1/8” Hex wrench (Allen Key)

Needle Nose Pliers

Flat Head Screwdriver

** Instructions are provide here as a guide only.  They are written for Polar Bear Water Distillers Assembly Instructions

1.Ensure that all of the parts that you require are available to you.

2.Turn main power switch on distiller off and drain the boiler tank. CAUTION: DRAIN VALVE MAY BE VERY HOT. Unplug cord from wall plug and wait at least 1 hour for distiller to cool.

3.Using the Robertson and Phillips screwdrivers (or 7/16” socket on a 26C-8 or 26-14), remove the Distiller covers. This will require disconnecting the water feed line and removing the brass reducer fitting on 26-CT, 26D-8, 26C-8 and 26-14 models. ENSURE THE SADDLE VALVE IS CLOSED BEFORE DISCONNECTING WATER FEED LINE.

4.Using the wire cutters, cut the new motor wires to the appropriate length (refer to the Parts Assembly Chart). Double check length against old motor before cutting!

5.Using the wire cutters, cut the fiberglass insulation to the appropriate length (refer to the Parts Assembly Chart). Slide insulation over both wires and inside motor housing approximately 1/4”.

6.Using the wire strippers on the crimping pliers, remove about 3/8” of insulation from the end of each wire.

7.Slide the appropriate terminal connector (refer to Parts Assembly Chart) on the end of the wire. The wire should be inserted far enough so that the wire insulation is butted against the inside of the connector. Using the crimping pliers, squeeze the neck of the connector until it is firmly attached to the wire.

8.Using the hex (allen) wrench, remove the set screw attaching the fan blade to the motor and slide blade up & over motor shaft. This may require GENTLY lifting the condenser coil. BE CAREFUL NOT TO BEND THE FAN BLADE OR COIL. Keep the fan blade and screw for reassembly.

9.Disconnect the fan wires from the distiller. Use the needle nose pliers for F250, Flag and Pigg connectors  (see main diagram) and use the flat screwdriver to undo the screws for Spade connections. Note where each wire was removed from and the routing of each wire before removing.

10.Using the wire cutters, cut the plastic tie strap attaching the old motor wires to the distiller body and note location of this tie.

11.Using the nut driver or adjustable wrench, remove the kep nuts on the bottom of the distiller attaching the old motor to the distiller body. Remove the motor.

12.Insert the new motor in the distiller body and reattach with the new kep nuts.

13.Connect the wires to the locations where the old wires were removed from using the same wire routes.  If you are unsure of where they should be connected, refer to the electrical schematic in your manual.  Ensure the wires do  not interfere with fan blade motion.

14.Using the plastic tie wrap, secure the wires over the fiberglass insulation to the base of the distiller where the old strap was attached. Cut the excess strap using the wire cutters.

15.Reattach the fan blade to the motor. Blade height must be adjusted so that there are no obstructions during rotations. Turn blade by hand to check for obstructions. Reattach covers. Ensure impurities drain valve is closed.  Reattach water feed line if it was removed and open saddle valve.

The distiller should now operate properly. If it does not, confirm that the wires are connected to the proper location by referring to your electrical schematic.

If they appear correct, we suggest you take your distiller to an authorized service representative, or call 1-780-477-1328 ask for service.

 


 

 Water Distiller Parts | Aromatherapy Stores Edmonton | Vitamin Stores Edmonton | Herbal Stores Edmonton | Natural Body Care Edmonton | Cooler Stores Edmonton | Distiller Stores Edmonton | Reverse Osmosis Water Filters Edmonton | Water Pumps Edmonton | Water Pumps for Sale Edmonton