Sold Out New

Thermal Reset Switch 120V/230V

$35.95

Reset Switch Polar Bear Water Distiller Part #100122 & Precision Water Distiller Part #060104

Part Thermal Reset Switch – New Style

Use on Both 120V and 230V

Universal switch – fits most distillers.

Polar Bear Water Distiller Part #100122  & Precision Water Distiller Part #060104

Polar Bear Water Distillers Models: 26E, 26E1, 26E2, 26M, 26-14, 26C, 26CT, 26C8, 26D, 26D4, 26D8, 42D, 42D5, 42D10, 42D25, 100L, 200L

Precision Water Distillers Models: 8-M, 5-3, 8-5, 8-8,  Life Mist, Traveler,  12-12, 12-20, 45-75

 

Please read complete instructions before replacing components.

Parts Referred To:

Part#                  Qty        Description                                    

100122               1             Switch, Boiler Tank Reset                

                           1           Plate, Reset, Lexan                                            

                                                                             

Tools Required

Red Robertson screwdriver

7/16” Socket w/ Ratchet or 7/16” Nut Driver

Assembly Instruction

Careful of wiring.  Number wires before removing them or remove them from old switch and put on new switch one at a time.

  1. Turn main power switch on distiller off and unplug cord for wall.
  2. Drain the boiler tank.  Caution: Drain Valve may be very hot.  Wait at least 1 hour for distiller to cool.
  3. Using the Robertson screwdriver, remove the Distiller front cover.
  4. Using a 7/16” socket or nut driver, remove nuts attaching the lexan reset plate to the boiler tank.  The rest switch will hang from it’s wires.
  5. Using the Robertson Screwdriver, loosen the screw on terminal 1 of the old reset switch. Disconnect the wires from the old switch and connect them to terminal 1 on the new reset.
  6. Repeat for terminals 2, 3 and 4.  When this is done, double check with the schematic and wiring list in your manual to ensure that the wiring is correct. 
  7. Place reset switch flush against boiler and reattach the lexan plate.  Replace front cover.  Ensure impurities drain valve is closed.

 

The distiller show now operate properly. If it does not, confirm that the wires are connected to the proper  location by referring to your electrical schematic. If they appear correct, we suggest you take your  distiller to an authorized service representative, or phone 1-780-477-1328 for assistance.

 


Distiller PartsHealth Food Stores Edmonton | Natural Food Stores Edmonton | Supplement Stores Edmonton | Health Supplement Stores Edmonton | Best Supplement Stores Edmonton | Aromatherapy Stores Edmonton | Vitamin Stores Edmonton | Herbal Stores Edmonton | Natural Body Care Edmonton | Cooler Stores Edmonton | Distiller Stores Edmonton | Reverse Osmosis Water Filters Edmonton | Water Pumps Edmonton | Water Pumps for Sale Edmonton

 

Reviews

There are no reviews yet.

Be the first to review “Thermal Reset Switch 120V/230V”